Electronic circuit breaker, signal contact: 1 N/C contact, nominal current: 1 A
Cod. Articolo: 0903032
Cod. Fornitore: 0903032
PHOENIX CONTACT
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Notes
General: When mounted in rows without convection cooling, the nominal device current should only be led to a maximum of 80% due to the thermal effect during continuous operation (100% operating factor). Special precautionary measures must be taken in systems or machines, to prevent components from restarting (e.g., use of a safety PLC). Parallel connection of multiple circuit breakers is not permitted.
Product properties
Type: DIN rail module, one-piece Product type: Device circuit breakers Product family: EC-E Number of positions: 1 No. of channels: 1 Insulation characteristics Degree of pollution: 2
Electrical properties
No. of channels: 1 Fuse type: Automatic device Switching capacity ICN: Active current limitation Fuse: electronic General Operating voltage: 24 VDC 18 VDC ... 32 VDC Nominal current IN: 1 A Rated surge voltage: 0.5 kV Tripping method: E (electronic) Required backup fuse: not required, integrated failsafe element Dielectric strength: max. 32 VDC (Load circuit) Switch off: Typ. 1.8 x IN Active current limitation: active Fuse: electronic Closed-circuit current range I0: typ. 25 mA ±5mA (When switched on) MTBF (IEC 61709, SN 29500): 7430000 h (at 25°C with 80% load) 6590000 h (at 40°C with 80% load) Voltage drop: 80 mV (at IN) Load circuit Max. capacitive load: 20000 µF Auxiliary contact Contact connection type: floating signal contact Minimum operating voltage Umin DC: 10 VDC Maximum operating voltage Umax DC: 30 VDC Minimum operating current Imin: 10 mA Max. operating current Imax: 0.5 A Indicator/remote signaling Connection name: Auxiliary contact Switching function: N/C contact
Connection data
Nominal cross section: 16.00 mm² Line+ / LOAD+ /0V Screw thread: M4 Tightening torque: ... 1.2 Nm Stripping length: 10 mm Conductor cross section rigid: 0.5 mm² ... 16 mm² Cross section AWG: 20 ... 6 (converted acc. to IEC) Conductor cross section flexible: 0.5 mm² ... 16 mm² Conductor cross section, flexible [AWG]: 20 ... 6 (converted acc. to IEC) Conductor cross-section flexible (ferrule without plastic sleeve): 0.5 mm² ... 10 mm² Flexible conductor cross section (ferrule with plastic sleeve): 0.5 mm² ... 10 mm² 2 conductors with same cross section, solid: 0.5 mm² ... 4 mm² 2 conductors with the same cross-section AWG rigid: 20 ... 12 (converted acc. to IEC) 2 conductors with same cross section, flexible: 0.5 mm² ... 4 mm² 2 conductors with the same cross-section AWG flexible: 20 ... 12 (converted acc. to IEC) 2 conductors with same cross section, flexible, with ferrule without plastic sleeve: 0.5 mm² ... 2.5 mm² 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 0.5 mm² ... 6 mm² Nominal cross section: 16 mm² Auxiliary contact Screw thread: M3 Tightening torque: ... 0.5 Nm Stripping length: 8 mm Conductor cross-section flexible (ferrule without plastic sleeve): 0.25 mm² ... 2.5 mm² Flexible conductor cross section (ferrule with plastic sleeve): 0.25 mm² ... 2.5 mm² Line+/LOAD+/0V Connection method: Screw connection Screw thread: M4 Tightening torque: 1.2 Nm Stripping length: 10 mm Conductor cross section flexible: 0.5 mm² ... 16 mm² Conductor cross section rigid: 0.5 mm² ... 16 mm² Conductor cross section AWG: 20 ... 6 Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.5 mm² ... 10 mm² Conductor cross section flexible, with ferrule without plastic sleeve: 0.5 mm² ... 10 mm² Auxiliary contactâ Connection method: Screw connection Screw thread: M3 Tightening torque: 0.5 Nm Stripping length: 8 mm Conductor cross section AWG: 24 ... 14 Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 2.5 mm² Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 2.5 mm²
Dimensions
Width: 12.5 mm Height: 83 mm Height NS 35/15: 90.5 mm Height NS 35/7,5: 83 mm Depth: 80 mm
Material specifications
Flammability rating according to UL 94: V0
Environmental and real-life conditions
Ambient conditions Degree of protection: IP20 (Housing) Ambient temperature (operation): 0°C ... 50°C (non-condensing) Ambient temperature (storage/transport): -20°C ... 70°C Humidity test: 96h, 95%RH, 40°C
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.
Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
Funzionale
Sempre attivo
L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
Preferenze
L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
Statistiche
L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici.L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
Marketing
L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.